Hızlı erişim, şık tasarım: Yeni sitemizi keşfedin. Kullanıcı deneyimini önceliğimiz yaptık, baştan aşağı yenilendik.
1500 TL ÜZERİ SİPARİŞLERDE ÜCRETSİZ KARGO
Hızlı erişim, şık tasarım: Yeni sitemizi keşfedin. Kullanıcı deneyimini önceliğimiz yaptık, baştan aşağı yenilendik.
1500 TL ÜZERİ SİPARİŞLERDE ÜCRETSİZ KARGO
Merck 108446 0001 Titriplex® III solution 1 AMP.
Merck 108446 0001 Titriplex® III solution 1 AMP.

Merck 108446 0001 Titriplex® III solution 1 AMP.

Ürün Kodu:1084460001
Hemen Al
WhatsApp
SEPETE EKLE
Ürün Açıklaması
\n\n\n\n\n\n\n\n\n\n\n\n
Description
Catalogue Number108446
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Product Information
HS Code2922 49 20
Quality LevelMQ100
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Physicochemical Information
Density1.04 g/cm3 (20 °C)
pH value7.8 (H₂O, 20 °C)
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Safety Information according to GHS
Hazard Pictogram(s)Hazard Pictogram(s)\n
Hazard Statement(s)H290: May be corrosive to metals.\nH315: Causes skin irritation.\nH319: Causes serious eye irritation.
Precautionary Statement(s)P234: Keep only in original packaging.\nP264: Wash skin thoroughly after handling.\nP280: Wear protective gloves/ eye protection/ face protection.\nP302 + P352: IF ON SKIN: Wash with plenty of water.\nP305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.\nP332 + P313: If skin irritation occurs: Get medical advice/ attention.
Signal WordWarning
Storage class8B Non-combustible, corrosive hazardous materials
WGKWGK 2 obviously hazardous to water
Disposal28\nAqueous solutions: Container D.
\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Storage and Shipping Information
StorageStore at +15°C to +25°C.
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Specifications
Concentration after dilution to 1 liter: c(C₁₀H₁₄N₂Na₂O₈ ∙ 2 H₂O) = 0.01 mol/l
Amount-of-substance concentration0.01000 mol/l
The concentration of this solution was determined with volumetric standard zinc (article number 1.02409). The determined titer at 20°C was 1.000 with an expanded measurement uncertainty of ± 0.004 (k=2 coverage factor for 95% coverage probability). The certified value is traceable to primary standard NIST SRM 682 (NIST: National Institute of Standards and Technology, USA) by means of volumetric standard zinc, measured in the accredited calibration laboratory of Merck KGaA, Darmstadt, Germany in accordance to DIN EN ISO/IEC 17025.

Çok Satanlar