Merck 105544 1000 Potassium Hydroxide Solution 1 LT.
Merck 105544 1000 Potassium Hydroxide Solution 1 LT.

Merck 105544 1000 Potassium Hydroxide Solution 1 LT.

Ürün Kodu:1055441000
Hemen Al
WhatsApp
SEPETE EKLE
Ürün Açıklaması
\n\n\n\n\n\n\n\n\n\n\n\n
Description
Catalogue Number105544
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Product Information
HS Code3824 99 92
Quality LevelMQ200
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Physicochemical Information
Density0.79 g/cm3 (20 °C)
Explosion limit2 - 13.4 %(V) (2-Propanol)
Flash point12 °C (2-Propanol)
Ignition temperature425 °C (2-Propanol)
pH value13 (H₂O, 20 °C)
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Safety Information according to GHS
Hazard Pictogram(s)Hazard Pictogram(s)\nHazard Pictogram(s)\nHazard Pictogram(s)\n
Hazard Statement(s)H225: Highly flammable liquid and vapour.\nH290: May be corrosive to metals.\nH315: Causes skin irritation.\nH319: Causes serious eye irritation.\nH336: May cause drowsiness or dizziness.
Precautionary Statement(s)P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.\nP233: Keep container tightly closed.\nP234: Keep only in original packaging.\nP240: Ground and bond container and receiving equipment.\nP303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.\nP305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.\nP403 + P233: Store in a well-ventilated place. Keep container tightly closed.
Signal WordDanger
Storage class3 Flammable liquids
WGKWGK 1 slightly hazardous to water
Disposal1\nStrongly contaminated halogen-free organic solvents: container A.
\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Safety Information
Categories of dangerhighly flammable, irritant
\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Storage and Shipping Information
StorageStore at +15°C to +25°C.
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Transport Information
Declaration (railroad and road) ADR, RIDUN 2924 , 3 (8), II
Declaration (transport by air) IATA-DGRUN 2924 , 3 (8), II
Declaration (transport by sea) IMDG-CodeUN 2924 , 3 (8), II, Segregation Group: 18 (Alkalis)
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Specifications
Formliquid
Amount-of-substance concentration0.0995 - 0.1005
Measurement uncertainty+/- 0.0003
TraceabilityNIST SRM
The amount-of-substance concentration of this volumetric solution is analyzed by our quality control laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025.\nThe concentration is determined by volumetric titration and refers to 20°C.\nThe amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.\nNote: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.\n*) The concentration of this volumetric solution decreases over time of storage. This is not a quality issue of this product, it is a property of this solution. Therefore we strongly recommend to perform a titer determination after opening the originally sealed bottle and every working day.